Product Description :

The "Multitech Engineers" The fully automatic Three pass heating systems essentially comprises of a fully automatic packaged Oil/Gas fired heater. As a result thermic fluid can be heated up to 300°C at near atmospheric pressure, with efficiency as high as 87% on NCV of Oil/Gas fuel.

The capacity ranges from 50000 kcal/hr to 10 lacs kcal/hr in Oil/Gas firing

Technical Specification

 

S. No.

Description

UNITS

ST-100

ST-200

ST-400

ST-600

ST-1000

ST-1500

1

HEAT OUTPUT

Kcal/Hr

1,00,000

2,00,000

4,00,000

6,00,000

10,00,000

15,00,000

2

MAX. OPERATING EMP.

O C

300

300

300

300

300

300

3

THERMIC FLUID

-

THERMINOL 66 OR EQUIVALENT

4

THERMIC FLUD FLOW

M³/Hr

7

10

30

40

70

110

5

BURNER TYPE

-

VERTICAL, DOWN FIRING PRESSURE JET ATOMISING FORCED DRAUGHT.

6

BURNER CONTROL

 

ON – OFF (OPTIONAL – HIGH/LOW OR MODULATING)

7

APPROX. THERMAL EFFICIENCY

%

87 + 2 ON NCV

8

APPROX. FUEL LDO : CONSUMPTION FO:

Kg/Hr

11.4

 

-

22.6

 

24

45

 

47.6

67.7

 

71.6

113

 

119

170

 

179

9

ELECTRIC SUPPLY

-

AC 415V  + 6%, 50Hz + 3%, 3 PHASE, 4 WIRE SYSTEM

 

10

CONNECTED LOAD

 

10.1

T.F. PUMP MOTOR

Hp/Kw

5/3.75

7.5/5.5

12.5/9.4

15/11.3

20/15

30/22.5

10.2

FUEL PUMP MOTOR

---------------0.5 / 0.37 -----------------------------

1/0.75

1/0.75

10.3

BLOWER MOTOR

1/0.75

2/1.5

2/1.5

3/2.25

5/3.75

7.5/5.63

10.4

CONTROL

0.5/0.37

10.5

ELECT.

PREHEATER-FO

-

4/3

4/3

8/6

12/9

12/9

10.6