P.F. Compensator- Automatic P.F. Correction Series - 12.5 KVAR to 100 KVAR

P.F. Compensator- Automatic P.F. Correction Series - 12.5 KVAR to 100 KVAR
Service Description

v Features:

NAAC P.F. Compensator series the power range goes from 12.5 kvar to 100 kvar. They are designed for small to medium load networks. They are highly reliable, cost effective solution for maintaining high network power factor.

They are ultimate solution for compensation of unbalanced loads. The compensation is released by measuring the reactive power of the system, through 3 CTs from all 3 phases. This makes it best suited even for most unbalanced loads apart from balanced loads.

They come equipped with following outstanding features:

Incomer TP MCCB 35kA

Micro processor based Neptune Phasetrac range of 3 phase P.F. Controller

Inbuilt 3 phase Analyzer

Compact wall mounting series with zinc passivated side clamps

Front louvers with Axial Flow Fan & Thermostat

Heavy Duty specially designed Neptune Capacitor Duty Contactors with high thermal current withstand capacity.

MCBs for control circuit protection

HRC Fuse or MCB (Series-D) for backup protection of capacitor banks.

High electrolytic grade Aluminium Busbar installed on SMC TP supports.

Discharge resistors (MOR)

Standard 1 Year warranty with NSL-10 Capacitor or 3 Year warranty with Long Life LL-10 Mono16 Capacitors.

Powder Coated- RAL 7035, Structure Finish

v Controller

Control Module with Data Logger

Measurement of A, V, PF, Cosφ, W, VAR, VA (ΣW, ΣVA, Σvar etc.)

Sense 1% of load current.

Auto/Manual mode selection with indicator light.

Automatic calculation of C/k value.

Program entry for targeted Cosφ value.

Number of capacitor steps are user definable.

The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds.

C+/NORMAL/C- condition lights indicate actual system state.

Over Voltage, Insufficient Compensation, Over Compensation state, alarm indicator lights with output contact.

Adjustable programmable Over Voltage protection for capacitor banks.

Micro Controller based digital design complying with international standards.

Flush mounting with rear panel connectors.

Designed to use with Current Transformer (.../5A).

Electrical & General Characteristics:

Power range: 12.5 - 100 KVAR (440V)

Mains voltage (working voltage): standard 440V (other voltage on request)

Rated frequency :50 Hz

Altitude: ≤2000 m a.s.l.

Relative humidity: 90% max. at 35ºC

Duty :continuous

Temperature class:-25+ 55ºC

Power supply line: Three-phase + ground + neutral (for 440V mains version only)

Relay current input signal: from CT on line.../5A

Relay voltage input signal: picked up internally.

Installation

Indoors, wall-mounted, in ventilated, non-dusty environment, away from direct sunlight.

Cable inlet from top

Disconnecting Switch

TP MCCB - 35 kA breaking capacity.

Mechanical Structure

The basic structure is made of white CRCA steel sheet with mounting plate Zinc galvanized.

The outer steel structural work is painted with cleaning treatment, degreasing, phosphating 70mm thickness paint with epoxy powder colour RAL7035.

Louvers on front door with Axial Flow Fan.

Capacitor mounted on side openable section from outside - offering easy replacement.

Wiring & Busbar

HR Copper wires are used for all the wiring connecting to Electrolytic grade Cu./Al. Busbar section.

Fuses / MCBs for Backup protection

HRC Fuse Link with base

The fuses are of 80kA breaking capacity.

Series-D TP MCBs for backup protection (optional)

Contactors

Equipped with Heavy Duty Capacitor Duty Contactor with early make contacts.

Coil voltage 230V, 50-60Hz.

Capacitors

Series NSL-10 Floppy Cap single-ph. elements wired in a delta connection rated 450V.

Optionally Long Life LL-10 Mono16 Series Capacitors, rated 450V.

Protection Devices

Each capacitor bank is equipped with discharge devices capable of reducing the residual voltage to below 10% of the rated capacitor voltage in about 30 seconds.

Screening Inspection 100%

Each automatic system manufactured undergoes the following tests & inspections:

Visual and dimensional inspection.

Check on mechanical efficiency.

Insulation test, 2.5kV for 1 min., between phases and ground.

Check on electrical efficiency at 440V, with verification of the total capacitance of the capacitors installed in the system.

Rating 440V,
50Hz

vItem Code

Capacitor Power at Un

10

20

30

40

50

KVAR

KVAR

KVAR

KVAR

KVAR

In(A)

Main Switch

A

Icc(kA)

Size

 

12.5

PFC-12.5 A

2.5

5

5

 

 

16.3

32

35

A

17.5

PFC-17.5-A

2.5

5

10

 

 

22.9

32

35

A

18

PFC-18-A

3.75

7.5

7.5

 

 

23.5

32

35

A

20

PFC-20-A

5

5

10

 

 

26.2

50

35

A

22

PFC-22-A

3.125

6.25

12.5

 

 

28.8

50

35

A

25

PFC-25-A

5

10

10

 

 

32.7

50

35

A

30

PFC-30-A

5

5

10

10

 

39.3

63

35

A

31

PFC-31-A

6.25

12.5

12.5

 

 

40.6

63

35

A

35

PFC-35-A

5

10

20

 

 

45.8

63

35

A

40

PFC-40-A

10

10

10

10

 

52.4

100

35

A

44

PFC-44-A

6.25

12.5

25

 

 

57.6

100

35

A

47

PFC-47-A

3.125

6.25

12.5

25

 

61.5

100

35

A

50

PFC-50-1-A

10

20

20

 

 

65.5

100

35

A

50

PFC-50-2-A

12.5

12.5

12.5

12.5

 

65.5

100

35

A

56

PFC-56-B

6.25

12.5

12.5

12.5

12.5

73.3

100

35

B

62.5

PFC-62.5-A

12.5

25

25

 

 

81.8

125

35

A

68

PFC-68-B

6.25

12.5

25

25

 

89

125

35

B

75

PFC-75-B

12.5

12.5

25

25

 

98.2

125

35

B

81.25

PFC-81.25-B

6.25

12.5

12.5

25

25

106.4

160

35

B

87.5

PFC-87.5-B

12.5

25

25

25

 

114.6

160

35

B

93.75

PFC-93.75-B

6.25

12.5

25

25

25

122.8

160

35

B

100

PFC-100-B

12.5

12.5

25

25

25

131

160

35

B

 

                   

 


Suffix Item Code with following Type nos.:

Type-1 - NSL-10 with HRC Fuses as backup protection
Type-2 - NSL-10 with MCB as backup protection
Type-3 - LL-10 with HRC Fuses as backup protection
Type-4 - LL-10 with MCB as backup protection

Size A : 700mm (W) x 275mm (D) x 700mm (H)
Size B : 700mm (W) x 275mm (D) x 900mm (H)