eNavigator, a sophisticated Power Analyser that enables the user to navigate the full scope of an electrical network & empowers to manage power efficiently. The instrument offers versatile and unmatched features and functions to monitor, profile, record events, control, log data, protect and even check the quality of an electrical system. eNavigator is built to be a one stop shop to meet your energy management needs.

Common Features

  True RMS Measurement

●  Simultaneous sampling of Volts & Amps

  Best parameters Grouping/Bright display

  Available in LED 4 row 6 digits each

●  Neutral current & RPM display

●  User programmable Password protection

  Auto scaling of Kilo, Mega, Giga and decimal point

  Clearance and Creepage distance meets UL 508 safety standard

  Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 Option)

  Upgradable to higher versions

●  Field programmable star, delta or single phase configuration

●  Interruption-recording of number of power failures

Salient Features

●  High / Low recording-Voltage, Current, Hz, W, VA, VAr, PF

  % of Unbalance V & A for all the phases

  THD for Voltage and Current

●  Individual Harmonics up to 31st level for V & A

  Ampere hour and PF average

  Programmable starting current in % of 5A Secondary. Default 0.4%

  Programmable parameter updates time 1 sec to 5 sec. Default 1 sec

  Programmable Auto scrolling time 1 sec to 5 sec. Default 5 sec

  Dynamic communication - user selectable register map

  Energy display programmable as counter or resolution based

  Energy resetting @ 999999 K* Multiplication factor

  Demand updating @ 1 sec

Generic Specification

Specifications

Details

Units

Conditions

Accuracy

Class 1(Default)
Class 0.5(Option)

%
%

Reading
FS

Burden V or I/ Phase

0.2 max

VA

per phase

Current Input

0.05 to 6

Amps

 

Auxiliary Supply

80 – 300

Volts

AC/DC

Display Resolution

4 row-6 digit

 

 

Baud Rate

600 bps to 19200 bps

bps

 

Operating Temperature

-10 to +55
-14 to 131

ºC
ºF

 

Storage temperature

-25 to 70
-13 to 158

ºC
ºF

 

Overload Current

10
50

Amps

Continuous
Max for 3 Sec

Isolation

2000

AC Volts

For 1 minute between communication & other circuits

Communication

Modbus RTU protocol

 

RS 485
RS 232(Optional)

 

Mechanical Specification

Features

Specifications

Units

Conditions

Panel Dimension Bezel

96 x 96

mm

 

Panel Cut-out

92 +0 -2 X 92 +0 -2

mm

 

Depth

50

mm

 

Weight

300
400

Grams

Unpacked
Shipping

The IEC standards

Standards Applicable

Tests of insulation properties

IEC 60060-1

Test of Accuracy requirements

IEC 62052-11

Test of electrical requirements

IEC 62052-11

Radio interference suppression

CISPR 22

Fast transient burst test

IEC 61000-4.4

Damped oscillatory waves immunity test

IEC 61000-4.12

Test of immunity to electromagnetic RF fields

IEC 61000-4.3

Test of immunity to conducted disturbances, induced by radio-frequency fields

IEC 61000-4.6

Test of immunity to electrostatic discharges

IEC 61000-4.2

Surge immunity test

IEC 61000-4.5

Test of the effect of the climatic environments

IEC 60068-2

Mechanical Tests

IEC 60068-2

Test of protection against penetration of dust and water

IEC 60529

Test of resistance to heat and fire

IEC 60695-2

Datalog Specification

No of Parameters

1

2

4

9

14

29

No of Records

8400

5600

3360

1680

1120

560

 

Optional features

  Dual port communication

●  Data logger maximum 8400 data with time stamp

  Digital Outputs 4 potential free contacts with programmable time delay

  Digital Input (Up to 4 inputs)

●  Analog Input voltage (0-1V) /current (0-20mA or 4-20mA), programmable to any full scale value

Model Selection Guide

Features

Parameters

EN8400

EN8400LM

EN8410

EN8410DMC

Basic

 

 

 

 

 

Line to Neutral Vlg

VLN Avg, Vr-N,Vy-N,Vb-N

*

*

*

*

Line to Line Vlg

VLL Avg, Vr-y,Vy-b,Vb-r

*

*

*

*

Line Current, Calculated IN

IAvg, Ir,Iy,Ib,In

*

*

*

*

Neutral Current Computed

ANC

*

*

*

*

Frequency, RPM (Generator application)

HZ, RPM

*

*

*

*

V & I Phase Angle

Vr,Vy,Vb,Ir,Iy,Ib,IN

*

*

*

*

Unbalance V & A

%V, %A

*

*

*

*

Power

 

 

 

 

 

Active Power

W Tot,Wr,Wy,Wb

*

*

*

*

Apparent Power

VA Tot, VA r,VA y,VA b

** VATot

*

*

*

Reactive Power

VAr Tot, VAr r, VAr y, VAr b

** VARTot

*

*

*

Power Factor

PF Avg, PFr,PFy,PFb

*

*

*

*

Energy / Integrated

 

 

 

 

 

Active Energy (Wh)

Wh

*

*

*

*

Apparent Power (VAh)

VAh

*

*

*

*

Reactive Energy (VArh)

VArh-Ind, VArh-Cap

 

*

*

*

Load Hours, Interruption, Life Timer

LH, Interrupt, Life count

*

*

*

*

Old Energy, Old Load Hours, Amp Hrs, PF Avg

Wh,VAh,VArh Ind/Cap, LH Old, Ah, PF Avg

*

*

*

*

Harmonics

 

 

 

 

 

Voltage THD

 

*

*

*

*

Current THD

 

*

*

*

*

K factor

 

*

*

*

*

Events

 

 

 

 

 

Voltage-VLN, LL High/ Low

VLN, VLL

*

*

*

*

Current High/ Low

A

*

*

*

*

Frequency High/ Low

Hz

*

*

*

*

W High/ Low

W

*

*

*

*

VA High/ Low

VA

*

*

*

*

VAr High/ Low

VAr

*

*

*

*

PF High/ Low

PF

*

*

*

*

Demand

Programmable to any one of them

 

 

 

 

Active Power (Wh)

Watt Hour

** Sliding window 1 relay

** Sliding window 2 relay

** RTC based

*** RTC based 4 relay

Apparent Power (VAh)

VA Hour

** Sliding window 1 relay

** Sliding window 2 relay

** RTC based

*** RTC based 4 relay

Reactive Power (VArh)

VAr Hour

 

** Sliding window 2 relay

** RTC based

*** RTC based 4 relay

Current Average

I Avg

 

** Sliding window 2 relay

** RTC based

*** RTC based 4 relay

Special features

 

 

 

 

 

40A Direct measurement

3 Phase

***

***

***

***

Neutral current measured

INM

***

***

***

***

Import / Export(RD)

Wh, VAh, VArh Ind/ Cap

**

**

**

**

Individual Harmonics

V & A upto 31st harmonics

 

**

**

**

 

* Default

** Optional feature, no restriction on combination of options

*** Restricted option, all restricted optional combination may not be possible